To setup multiple ATA's to the engin network, you will need to change the SIP and RTP ports incrementally under the SIP and LINE 1 tabs for your Sipura ATA.
For example, if you have 2 x Sipura SPA-2000's, you will need to setup 4 port forwarding rules and also change the SIP and RTP ports respectively for each ATA. For simplicities sake, we have called the first ATA " SPA Y" and the second ATA " SPA Z" in the following example.
For the first ATA
- Set up a port-forwarding rule for UDP 5060-5061 to be forwarded to your "SPA Y" IP address
- Set up a port-forwarding rule for UDP 16384 -16386 to be forwarded to your "SPA Y" IP address
For the second ATA
- Set up a port-forwarding rule for UDP 5062-5063 to be forwarded to your "SPA Z" IP address
- Set up a port-forwarding rule for UDP 16387 -16389 to be forwarded to your "SPA Z" IP address