Overview
Step 1: Accessing the Linksys WRT54GP2 or RT31P2
- Login to your device by the IP address of 192.168.15.1
- Enter the username: admin, and password: admin
- When you have successfully authenticated, enter http://192.168.15.1/Voice_adminPage.htm into your web browser
- Enter the username: admin, and your SIP password
Step 2: The Regional Page
- Go to the Regional tab
- Make the following changes
Dial tone: 400@-19,425@-19,450@-19;10(*/0/1+2+3)
Busy Tone: 425@-19;10(.375/.375/1)
Reorder Tone: 425@-19, 425@-29;60(.375/.375/1,.375/.375/2)
Ring Back Tone: 400@-19,425@-19,450@-19;*(.4/.2/1+2+3,.4/2/1+2+3)
MWI Dial Tone: 400@-19,425@-19,450@-19;2(.1/.1/1+2);10(*/0/1+2)
Ring1 Cadence: 60(.4/.2,.4/2)
- Go to the Control Timer Value Heading
- Change Interdigit long Timer to 6
Step 4: Change FXS Impedance
- Go to the Miscellaneous Heading
- Change FXS Port Impedance to 220+820||115nF