Step 1: Accessing the Linksys WRT54GP2 or RT31P2
- Login to your device by the IP address of 192.168.15.1
- Enter the username: admin, and password: admin
- When you have successfully authenticated, enter http://192.168.15.1/Voice_adminPage.htm into your web browser
- Enter the username: admin, and your SIP password.
Step 2: Accessing the Advanced Settings
- Go to the SIP tab
- Under the SDP Payload section, change the G729a Codec name to G729 (i.e. remove the a).
Step 3 :Setting up a Time Server
You can configure the Linksys PAP2 to automatically retrieve the current date and time (Including daylight savings). To do this you will need to enter in a NTP server.
- Go to the System tab and add the following NTP server
- Enter Primary NTP Server: au.pool.ntp.org
Step 4 :Setting up Daylight savings
For NSW these settings will work:
- Time Zone: GMT+11:00
- Daylight Saving Time Rule: start=3/-1/7/3;end=10/-1/7/2;save=-1
Step 5 :Proxy and Registration – LINE 1
- Go to LINE 1 and add the following authentication information.
- Enter your user data as per the image below
- Proxy: byo.engin.com.au
- Use Outbound Proxy: Yes
- Outbound Proxy: mel or syd.byo.engin.com.au
- Register Expires: 900
- Display Name: Your Name
- User ID: Your engin phone number
- Password: your SIP password
- Use Auth ID: Yes
- AUTH ID: Your engin phone number.
- Dial plan:
- Supported codec’s: g729a & g711a
Step 6 :Audio Configuration
Next, change the Audio Configuration heading.
- The following change is required.
- Preferred Codec: G711a.
(Copy and paste the following dial plan at the bottom of the LINE 1 page)
(*xx|13[1-9]xxxS0|1[38]00xxxxxxS0|190xxxxxxx!|000S0|0011xxxxx.|[2-9]xxxxxxxS0|0[2-9]xxxxxxxxS0)
Description
*xx = special *number dial
13[1-9]xxx = dial pizza numbers etc
1[38]00xxxxxx = 1300 and 1800 numbers
190xxxxxxx! = Disable 1900 numbers (remove ! to enable)
000S0= Fire/Police/Ambulance
0011 = International
[2-9]xxxxxxx = any local number
0[2-9]xxxxxxxx = any interstate numbers