Search VoIP Help:
Adv search
|
Browse by Manufacturer:
|
|
|
How do I configure my SPA-3102 PSTN to VoIP gateway? |
|
|
|
|
|
Views: 1399
Votes: 0
|
|
Posted: 14 Sep, 2007
by: Engin *.
Updated: 22 Aug, 2008
by: Engin *.
|
|
Overview
Step 1: Accessing the Linksys 3102 ATA
- Connect your phone into the PHONE port of your Linksys ATA
.
- Dial **** then 110#, the SPA will announce the current IP address
- Once you have the IP address
of your SPA-3102 you can access the web interface by opening a web browser and typing the following in the Address: http:/ /< IP Address
of SPA-3102 > For example: http://192.168.1.10
- Enter the username: user and and your SIP password
- You should now see the Sipura SPA-3102 Phone Adapter Configuration screen.
- Click on the admin login ink
- Enter the username: admin and your SIP password
- Click on the advanced Link
Step 2: The PSTN
line tab
- Go to the PSTN
Line tab
- Make sure LINE 1 is set to enable
Step 3: Configuring your SIP account on the PSTN
tab
- Go to the PSTN
Line tab
- Make sure LINE 1 is set to enable
- Re-enter your Authentication settings as per LINE 1.
Step 4: Configuring PSTN
settings
- Under the PSTN
to VoIP gateway
heading make these changes:
- Select PSTN
to VoIP gateway
: Yes
- Select PSTN
Ring Thru Line 1: Yes
- PSTN
Caller Auth Method: None
- PSTN
Access List: 0280040000, 0280040001, 0280040002.
- Under the FXO
timer heading select how long you want the PSTN
to ring for by changing the PSTN
answer delay value
- Under the PSTN
disconnection Detection make these changes:
- PSTN
Silence Threshold: medium
- Disconnect Tone: 425@-30,425@-30;1(.375/.375/1+2)
- Submit all changes

|