Search VoIP Help:     Adv search
Browse by Manufacturer:
KB Number

I have an engin SPA-3102, how do I assign a static IP address and configure port forwarding via my Dynalink RTA 1335 /1025W series modem?

Views: 1356
Votes: 0
Posted: 05 Sep, 2007
by: Engin *.
Updated: 30 Nov, 2007
by: Engin *.
Overview


Step 1: Find your IP
  1. Disconnect your PSTN line from the LINE socket. By the term "PSTN ", we are referring to your regular landline provider
  2. Dial **** 110 # to listen to your IP address of your SPA-3102
Step 2: Enter your IP address via the web interface
  1. Enter the IP address into your web browser
  2. Go to the WAN Setup menu
  3. Select Static IP
  4. Enter IP address : 192.168.1.10
  5. Enter Gateway Address: 192.168.1.1
  6. Enter Subnet mask: 255.255.255.0
  7. Submit all changes


Step 3: Login to the Dynalink RTA series modem
  1. Start your web browser and type the private IP address of the ADSL Router in the URL field: http://192.168.1.1
  2. After connecting to the device, you will be prompted to enter username and password. By default, the username is admin and the password is admin.
Step 4: Configure Port Forwarding.
  1. Go to the Advanced Setup> Virtual Server >Port Forwarding
  2. Click Add
  3. Enter a " User Defined" Rule
  4. Name the rule " engin"
  5. Enter 192.168.1.10 for the address to forward to.
  6. Enter Protocol as UDP
  7. Enter start and finish port 5060 (External and Internal Packet )
  8. Repeat the same process for ports 16384-20384 (External and Internal Packet )
  9. Click " Apply"


Others in this Category
document I have an engin voicebox series 1 or 2, how do I assign a static IP address and configure port forwarding via my Dynalink RTA series modem?
document I have an engin 221, how do I assign a static IP address and configure port forwarding via my Dynalink RTA series modem?



RSS