Search VoIP Help:
Adv search
|
Browse by Manufacturer:
|
|
|
How do I setup the PSTN to VoIP gateway feature on the SPA-3102? |
|
|
|
|
|
Views: 1815
Votes: 0
|
|
Posted: 29 Jun, 2007
by: Engin *.
Updated: 08 Aug, 2008
by: Engin *.
|
|
Overview
Step 1: Accessing your unit
- Connect your phone into the PHONE port of your Linksys ATA
.
- Dial **** then 110#, the SPA-3102 will announce the current IP address
- Once you have the IP address
of your SPA-3102 you can access the web interface by opening a web browser and typing the following in the Address: http:/ /< IP Address
of SPA-3102> For example: http://192.168.1.10
Step 2: Access PSTN
Settings
- Go to Voice > Admin Login > Advanced
- Click the URL
- If a username and password login appears enter username" admin, and your engin SIP password.
- If you decide to lock down the user side of the SPA-3102, the username is"user"
Step 3: Configuring your engin SIP settings on the PSTN
tab
- Go to the PSTN
Line tab
- Make sure LINE 1 is set to enable
- Re-enter your Authentication settings as per LINE 1.
Step 4: Setting Up the PSTN
to VoIP Gateway
- Select PSTN
to VoIP gateway
: Yes
- Select PSTN
Ring Thru Line 1: Yes
- PSTN
Caller Auth Method: None
- PSTN
Access List: 0280040000, 0280040001, 0280040002.
- Select how long you want the PSTN
to ring for by changing the PSTN
answer delay value
- PSTN
Silence Threshold: medium
- Disconnect Tone: 425@-30,425@-30;1(.375/.375/1+2)
- Submit all changes
|